Publication Beamlines Strategic Pillar
Zhu, Ning; Chapman, Dean; Cooper, David; Schreyer, David J.; Chen, Xiongbiao et al. (2011). X-Ray Diffraction Enhanced Imaging as a Novel Method to Visualize Low-Density Scaffolds in Soft Tissue Engineering. Tissue Engineering - Part C: Methods 17(11) , 1071-1080. 10.1089/ten.tec.2011.0102. BMIT-BM Materials
Bewer, Brian; Chapman, Dean (2010). Development of an x-ray prism for analyzer based imaging systems. Review of Scientific Instruments 81(8) , 085108. 10.1063/1.3478018. BMIT-BM Materials
Asai, Juhachi; Wysokinski, Tomasz W.; Smith, Sheldon; Chapman, Dean (2008). Radiological considerations for POE-1 photon shutters, collimators and beam stops of the Biomedical Imaging and Therapy beamline at the Canadian Light Source. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators. Spectrometers. Detectors and Associated Equipment 585(1-2) , 1-11. 10.1016/j.nima.2007.10.049. BMIT-BM, BMIT-ID Materials
Wysokinski, Tomasz W.; Chapman, Dean; Adams, Gregg; Renier, Michel; Suortti, Pekka et al. (2007). Beamlines of the biomedical imaging and therapy facility at the Canadian light source—Part 1. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators. Spectrometers. Detectors and Associated Equipment 582(1) , 73-76. 10.1016/j.nima.2007.08.087. BMIT-BM, BMIT-ID Health
Challa; Pradyumna R. (2012). X-ray Investigations of PEMFC Gas Diffusion Layers (GDLs). Supervisor: Bazylak, Aimy. Ontario, Canada: University of Toronto. https://tspace.library.utoronto.ca/handle/1807/33359. BMIT-BM Materials
Landheer; Karl (2012). Synchrotron-based coherent scatter x-ray projection imaging using an array of monoenergetic pencil beams. Supervisor: Johns, Paul C.. Ontario, Canada: Carleton University. https://curve.carleton.ca/cd484aa0-f00d-4bb7-97a7-60f5226c80d8. BMIT-BM Materials
Morrell; Brian (2012). Optical characterization of samarium-doped fluorophosphate glass for x-ray dosimetry for microbeam radiation therapy at the Canadian Light Source. Supervisor: Kasap, Safa O.; Chapman, Dean. Saskatchewan, Canada: University of Saskatchewan. https://harvest.usask.ca/handle/10388/ETD-2012-06-486. BMIT-BM Materials
Muzar; Edward (2012). Synthesis, Stability and Characterization of Indirect Conversion Materials for the Measurement of Dose at a Synchrotron Biomedical Imaging and Therapy Beamline. Supervisor: Kasap, Safa O.; Chapman, Dean. Saskatchewan, Canada: University of Saskatchewan. http://hdl.handle.net/10388/ETD-2012-07-581. BMIT-BM Materials
Wiebe; Sheldon (2012). Interpretation of Refraction Images in Synchrotron Based Imaging Techniques Using Growth Plate Injury Specimens in an Animal Model. Supervisor: Chapman, Dean; Juurlink, Bernhard. Saskatchewan, Canada: University of Saskatchewan. https://ecommons.usask.ca/handle/10388/ETD-2011-11-219. BMIT-BM Health
Walker; T. (2011). Authentic scientific inquiry, student engagement and transformational learning: are they related?. Canada, SK: CLS. https://harvest.usask.ca/bitstream/handle/10388/ETD-2011-09-224/ThesisVersionFinalFormatJan2012.pdf?sequence=5. BMIT-BM, FAR-IR, HXMA, MID-IR, SGM, SM, SXRMB, VESPERS, VLS-PGM
Yijing Guan (2010). Characterization of Alginate Scaffolds using X-ray imaging techniques. Supervisor: Chen, Daniel X.B.; Chapman, Dean. Saskatchewan, Canada: University of Saskatchewan. https://ecommons.usask.ca/handle/10388/etd-10192010-194128. BMIT-BM Materials
Popoola; Aminat Adeola (2009). A fiducial subject pre-alignment system for the Biomedical Imaging and Therapy Beamlines at the Canadian Light Source. Supervisor: Chapman, L. Dean; Adams, Gregg P.. Saskatchewan, Canada: University of Saskatchewan. http://hdl.handle.net/10388/etd-04142009-181529. BMIT-BM Materials
Alagarsamy; Nagarajan (2007). Mechanical support design of analyzer for a diffraction enhanced x-ray imaging (DEI) system. Supervisor: Szyszkowski, Walerian; Chapman, L. Dean. Saskatchewan, Canada: University of Saskatchewan. https://ecommons.usask.ca/handle/10388/etd-05172007-160800. BMIT-BM Materials
Zhu; Ning (2012). Development and in vitro characterization of three dimensional biodegradable scaffolds for peripheral nerve tissue engineering. Supervisor: Chen, Daniel; Chapman, Dean. Saskatchewan, Canada: University of Saskatchewan. https://ecommons.usask.ca/handle/10388/ETD-2012-05-465. BMIT-BM Materials
Zhu; Ying (2012). Bent laue crystals in biomedical x-ray imaging application. Supervisor: Chapman, Dean L.; Nichol, Helen. Saskatchewan, Canada: University of Saskatchewan. https://ecommons.usask.ca/handle/10388/ETD-2012-11-768. BMIT-BM, HXMA Materials